Home > Products > LPCB Approved Addressable Fire Alarm Detection System Control Panel
LPCB Approved Addressable Fire Alarm Detection System Control Panel
Click on the image to view the original image
Product: views:7LPCB Approved Addressable Fire Alarm Detection System Control Panel 
Branch: Asenware
Type: Network,Addressable
Unit Price: Negotiated
Min.Order:
Supply:
Delivery: Shipment within days since the date of payment
Valid until: Long Term
Updated on: 2019-10-17 02:58
  Negotiated
Product Details
Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
Asenware
Model Number:
AW-AFP2189
Type:
Network,Addressable
AC Input Voltage:
AC 220V ± 20% 50Hz
AC Input Power:
120W
Power Supply:
AC 220V 50Hz ; DC 24V 6A
Output Contact Capacity:
AC 220V 1A ; DC 27.6V 3A
Capacity:
324 addresses
Temperature Range:
-10℃ to +50℃
Humidity:
≤95%
Services:
OEM/ODM
Certificate:
CE,LPCB,EN54-4
Supply Ability
Supply Ability:
1000 Piece/Pieces per Month
Packaging & Delivery
Packaging Details
carton box
Port
shenzhen
Product Description

Addressable Fire Alarm Control Panel

AW-AFP2189 fire alarm control panel is a new generation of fire alarm control panel launched,in order to meet the engineering design demand,the control unit is provided with both linkage and control functions,It can support uses of other related products of company to form an integrated alarm and linkage control system,which is perfectly suitable for the application of small and medium-size fire alarm and firefighting and linkage integrated control system.

Features

1. Adopts the latest generation of high-speed microprocessor. Data processing rate and data storage capacity reach 100-fold and 1000-fold increase, respectively, compared to traditional technologies

2. AW-AFP2189 is provided with 4.3" color display screen (LCD), with a display resolution of 430×272.

3. The operation interface imitates Windows menus and window interfaces and is almost the same as the computer operating and using habits, thus facilitates the learning.

4. Operation and control are flexible and convenient through the standard USB-interfaced computer keyboard and mouse + the panel buttons are used as field programming devices.

5. T9 pinyin input method is provided and texts can be input easily and freely.

6. Use smart U disk (optional), which can be used to copy or restore setup file and historical file of the system, thus facilitating the system maintenance.

7. It adopts the non-polarity two-bus intelligent alarm linkage pattern and can connect 324 intelligent detectors or intelligent modules at most. The addresses of module detectors can be mix-programmed (optional 1-324)

8. It supports interconnection of 20 AW-AFP2189 control units and the maximum system capacity after networking reaches 20×324=6480 (alarm point)

9. The maximum capacity of linkage control unit of a single equipment: 10 points

10. The system has the function of recording operation history: 1000 pieces of historical fire alarms, historical requests, historical feedbacks, historical faults and historical operations, respectively

11. The user may customize the equipment type, which can facilitate the system integration

12. It has the modular manual single-point start/stop functions, which can facilitate field debugging and testing

13. It has the single-point detector/module testing function, the detector working status and test data are clearly displayed

14. The system is provided with a dedicated mini-printer as standard, which is used to print various operating statuses of the system immediately

15. It can be accessed with area indicating panels, building indicating panels and floor indicating panels, which will extend display information of the control unit to corridor and other locations

16. It can be connected with PC to achieve city networking.

17. The system carries out the hierarchy management of multi-level users and the users of different levels are granted with corresponding operating system permissions, which is convenient for system management

18. It is possible to update the system on the field or remotely to ensure the system operates stably and reliably

Specifications

Addressable Fire Alarm Control Panel  # AW-AFP2189
Type:
Addressable
Mains power supply:
AC 220V±20%,50/60Hz or DC24V
Backup power supply:
DC24V maintenance-free battery,12V/5Ah
Circuit bus:
Two-wire system,total length≤1500m
Voltage V of the circuit bus:
+20V ≤V ≤ +26V(When the DC power is operating)
+24V ≤V ≤ +26V(When the AC power is operating)
System operating enviroment:
-10℃~+55℃,≤95%(40℃±2℃,no condensation)
Capacity:
324 points
Detailed Image
Related Products
Packing & Delivery
Our Service

* OEM & ODM is available.
* Support factory inspection.
* Standard quality control system.
* Different choices of payment and delivery.
*Independant R&D dept, designing dept,to meet your special need.
* Whole set of technical supports and with abroad projects experience.
* We are manufacturer, offer better price better production control.
* Sample order, customized order, bulk order are supported.
* Reliable after-sales service, with one year waranty.

Our Company
Certifications
FAQ

Q1. Can I have a sample order for addressable fire alarm control panel?
A: Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.

Q2. What about the lead time?
A:Sample needs 3-5 days, mass production time needs 1-2 weeks for order quantity more than

Q3. Do you have any MOQ limit for addressable fire alarm control panel?
A: Low MOQ, 1pc for sample checking is available

Q4. How do you ship the goods and how long does it take to arrive?
A: We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Airline and sea shipping also optional.

Q5. How to proceed an order for addressable fire alarm control panel?
A: Firstly let us know your requirements or application.
Secondly We quote according to your requirements or our suggestions.
Thirdly customer confirms the samples and places deposit for formal order.
Fourthly We arrange the production.

Q6. Is it OK to print my logo on addressable fire alarm control panel product?
A: Yes. Please inform us formally before our production and confirm the design firstly based on our sample.

Q7: Do you offer guarantee for the products?
A: Yes, we offer 2-5 years warranty to our products.