Homepage|Business Center|Save the Page|Get the App
普通会员

Shenzhen Asenware Test & Control Technology Co., Ltd.

Product Category
  • No Category Yet
Search
 
Link
  • No links
Home > Products > EN54 part 2&4 standard Fire Central Control Panel Each Zone
EN54 part 2&4 standard Fire Central Control Panel Each Zone
Click on the image to view the original image
Product: views:7EN54 part 2&4 standard Fire Central Control Panel Each Zone 
Branch: Asenware, Asenware
Unit Price: Negotiated
Min.Order:
Supply:
Delivery: Shipment within days since the date of payment
Valid until: Long Term
Updated on: 2019-10-17 02:59
  Negotiated
Product Details
Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
Asenware, Asenware
Model Number:
AW-D116
Product Description:
EN54 part 2&4 standard Fire Central Control Panel Each Zone
Executive Standard:
GB19880-250
Mains Supply Voltage:
110VAC or 240VAC
Circus Bus:
2-wire Bus System
Fire Output Type:
NC and NO relay
Color Option:
Red; Black; White; Grey; Other customized colors
Support Service:
OEM;ODM is welcomed
Selling Point:
With fire relay of each zone
Applicable:
Construction buildings; Home secutiry;Restaurant;Hospital etc.
Supply Ability
Supply Ability:
1000000 Piece/Pieces per Year
Packaging & Delivery
Packaging Details
EPE inside, carton outside.
Port
Shenzhen,China
    EN54 part 2&4 standard Fire Central Control Panel Each Zone
 
 
Selling Point: 4 zone fire alarm panel, with fire relay output of each zone.

 
Product Description

  

* AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.

* It is modularized design, the panel can expend from 1 zone to 32 zones easily.

* It has 2 level control mode by a lock

* It has 24VDC and 5VDC power supply output.

* It has FIRE and FAULT signal output.

* It has 2 general sounders output.

* Each zone has 1 circuit detectors input .

* Each zone can be disable by a button.

* It has RESET button to reset the panel.

* It has SILENCE button to stop BUZZER and SOUNDERS.

* It has EVACUATE button to start a manual fire alarm immediately.

* It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.

* It has an optional GSM module for fire alarm by SMS .

* It is economic, user-friendly and easy maintenance.

fire alarm control panel each zone fire reply output

 

 

ITEM1 Zone panel2 Zone panel4-8 Zone panel4-32 Zone panel
Model No.AW-CFP2166-01AW-CFP2166-02AW-CFP2166-04-08AW-CFP2166-04-16
Power Specification           
Mains supply voltage110VAC or 240VAC   
Internal power supply27.2VDC   
Total output current limited500mA @ 240VAC 3A @ 240VAC 
Main supply monitor for faultYes   
Battery protection for low voltageYes   
Batteries (default configuration)12V2AH*2   
Detector Circuit Specification    
Number of circuit124-84-32
Line fault monitor for open circuitYes   
Line fault monitor for short circuitYes   
Line fault monitor for detector removalYes, if End of Line Monitor Unit fitted in place of End of Line Resistor   
End of Line device6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)   
Detector continuity diodesSilicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)   
Call point resistor value470 to 680 Ω, 0.225 or 0.5 watt   
Maximum number of smoke/heat detectors per zone20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.   
Maximum number of manual call points per zoneNo limit   
Sounder Circuit Specification    
Number of general circuits2   
End of line resistor value6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)   
Line fault monitor for open circuitYes   
Line fault monitor for short circuitYes   
Outputs fused AT400mA   
Maximum number of bells @ 20mA of each Sounder output20   
Fuses    
Battery fuse1.5A F 20mm   
Sounder outputs500mA F 20mm   
Fire Output    
Output typeNC and NO relay   
Maximum current100mA   
Connection Block    
Largest acceptable conductor size2.5mm2   
Smallest acceptable conductor size0.75mm2   
Size and Weight    
Dimensions(mm)272X200X70320X231X90395X502X124362X565X124
Weight (without batteries)4kg5kg7kg8kg
Weight (with batteries)5.8kg6.8kg19.6kg12.5kg

fire alarm control panel each zone fire reply output

 

More Images

        

System Diagram of The Conventional Fire Alarm Panel

 

 

 

 

The Whole Fire Alarm Control Panel System

 

The conventional fire alarm control system 2166 series match the below detectors and accessories:
Image    
Name conventional photoelectric smoke detector conventional fixed temperature heat detector conventional smoke and heat combind detector conventional manual call point/break glass conventional hooter/horn conventional fire bell conventional flash light
Model No. AW-CSD311 AW-CTD805 AW-CSH202

AW-CMC2166-1

AW-CMC2166-5

 AW-CSS2166-2 AW-CBL2166-A AW-CBL2166

 

  fire alarm control panel each zone fire reply output

 

 

Applicated in Various Places and Environment 

fire alarm control panel each zone fire reply output

 

Packaging & Shipping

 

 

Company Information

 

Our Services

 

 

* Over 10 years" experience.

* Prompt response.

* OEM & ODM available.

* Support factory inspection.

* Standard qulity control system.

* Different choices of payment and delivery.

* Independant R&D dept, designing dept,to meet your special need.

* Whole set of technical supports and with abroad projects experience.

* We are manufacturer, offer better price better production control.

* Sample order, customized order, bulk order are supported.

* Reliable after-sales service, with one year waranty.

  fire alarm control panel each zone fire reply output

 

FAQ

 

 

 

* Is Asenware Company a factory ?
Yes, we have Factory in Zhongshan, Office in Shenzhen, Headquarter in London.

* What is our payment term ?
T/T; L/C; Western union.

* How long is the delivery time ?
Usually about 2 to 7 days. Mass production about 3 weeks.

* Do we have technical support ?
Yes, we have a professional engineering team.

* How to assure the quality ?
Firstly, all of our materials and components pass the serious China Quality Standard and Control.

Secondly, all of our finished products should pass Asenware Quality Check System before export.

Thirdly, our products can be provided to test and cetify by Authories according to customer"s special need.

* Do we have warranty ?
Yes, One year or more depends.

* Sample for testing ?
Yes, Stock sample or Customized sample is available.

* Procedure to Purchase our products ?

Inquiry --- Offer --- Dicssion --- Confirmation --- Order --- Deposit --- Production --- Payment --- Shipment --- Arrival --- Finished --- Feedback --- Repeat Order.

* The ways to contact us ?
Offical web "asenware.en.alibaba.com"; Domestic and Abroad Exhibitions; Factory Tour; Email & Phone etc.

 fire alarm control panel each zone fire reply output

 

     Inquire now ! !

 

 

with Fire relay of each zone     fire alarm system

Zone fire relay output                fire alarm control panel
Each zone fire relay                   fire alarm panel
Each zone fire output                security system alarm panel

 

询价单
total0items  Comments