Home > Products > FM200 automatic fire extinguisher system
FM200 automatic fire extinguisher system
Click on the image to view the original image
Product: views:5FM200 automatic fire extinguisher system 
Branch: ASENWARE
Type: Standalone Networking
Unit Price: Negotiated
Min.Order:
Supply:
Delivery: Shipment within days since the date of payment
Valid until: Long Term
Updated on: 2019-10-17 03:13
  Negotiated
Product Details
Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
ASENWARE
Model Number:
AW-FM
Capacity:
70L/90L/100L/120L/150L/180L
Agent:
Hfc-227ea
Pressure:
2.5/4.2/5.6MPa
Fire:
Class a/B/C
Clynder Color:
Red
Type:
Standalone Networking
Working Temperature:
0 Degree to 50 Degree
Packaging:
Wooden
Work:
Fire Detection System
Discharging Time:
Less 10s
Supply Ability
Supply Ability:
10000 Piece/Pieces per Year mass quantity is welcomed
Packaging & Delivery
Packaging Details
use wooden to pack FM200 cylinder
Port
shenzhen

 

Product Description

 FM200 automatic fire extinguisher system   

The FM-200 Fire Suppression System is an engineered system  utilizing a fixed nozzle agent distribution network. The system is designed and installed in accordance with the National Fire Protection Association (NFPA) Standard 2001, "Clean Agent Fire Extinguishing Systems." When properly designed, the FM-200 system will suppress surface burning fire in Class A, B, and C hazards.

The clean agent fire extinguishing system shall perform as outlined in the following sub-sections.
A. Achieve a 6.25% (v/v) extinguishing concentration for Class A (Surface Type Fires) hazards.

B. Achieve a 8.70% (v/v) or greater, as required, extinguishing concentration for Class B (Flammable Liquids) hazards.

C. Achieve a 7.00% (v/v) extinguishing concentration for Class C (Energized Electrical Equipment) hazards.

D. Within 10 seconds, the clean agent fire extinguishing system shall discharge 95% of the required suppression agent mass.

E. The clean agent fire extinguishing system shall consist of one or more Asenware Fire Systems agent cylinders and related equipment. The cylinders may be either connected to a discharge pipe arrangement separately or connected to a common manifold and discharge pipe arrangement. The agent cylinders shall be filled with FM-200, and super pressurized with dry nitrogen to a working pressure of 360 PSIG at 70°F (24.8 bar gauge at 21°C).

FM200 technical parameters


Tempreture ºC
0-50
20ºC Storage pressure(Mpa)
 
2.54.25.6
20ºCmaximum working pressure
(Mpa)
 
4.26.78
Cylinder (L)10070/90/100/120/150/18090
AGENT kg/m3≤1120≤1120≤1080
Nozzal pressure≥0.6≥0.7≥0.8
Discharge timeComputer room ≤8  others≤10
concentration8-10%


FM 200 system operation
A. The clean agent fire extinguishing system shall consist of FM-200, agent cylinder(s),  actuation hardware and  discharge nozzle(s) attached to a pipe network

 

Agent – FM-200 (HFC-227ea) is a clean, gaseous agent containing no particles or oily residues. It is produced under ISO
9002 guidelines to strict manufacturing specifications ensuring product purity. FM-200 leaves no residue or oily deposits on
delicate electronic equipment, and can be removed from the protected space by ventilation. FM-200 is thermally and chemically stable, but without the extremely long atmospheric lifetimes  associated with other proposed halon replacements. The atmospheric lifetime of FM-200 has been determined to be 33 years. The EPA does not consider FM-200 to be a long-lived substance when discharged, and as such, has placed no restrictions on its use



B Detection System - The ASENWARE Detection System is used where an automatic electronic detection system is required to actuate the FM-200 suppression system. This detection system is
used to actuate a single, fixed, fire suppression or alarm system based on inputs received from fire detection devices. The detection circuits can be configured using cross, counting, independent or priority-zone (counting) concepts. The detection system has been tested to the applicable FCC Rules and Regulations for Class A Computing devices.

   FM200 Fire Fighting Gas Extinguishing System show

 

 

  FM200 Fire Fighting Gas Extinguishing System parameters

ITEM

ELECTRICAL RATING

COMMENT

Mains Supply

90 to 270VAC, 50Hz/60H(100 Watts maximum)

 

Battery Type

Two 12 Volt sealed lead acid in series.

7Ah maximum

R0V Output

Fused at 500mA with electronic fuse

1.6Amp total load over all circuits

Sounder Outputs

21 to 28V DC Fused at 500mA with electronic fuse

 

Fault relay contact rating

5 to 30 VDC 1A Amp maximum for each

Volt free changeover contact

Local fire relay contact rating

5 to 30 VDC 1A Amp maximum for each

 

Volt free changeover contact

First stage contact rating

5 to 30 VDC 1A Amp maximum for each

 

Volt free changeover contact

Second Stage Contact Rating

 5 to 30 VDC 1A Amp maximum for each

Volt free changeover contact

Extract Contact Rating

 5 to 30 VDC 1A Amp maximum for each

 Volt free changeover contact

No. of detection circuits

Four 21 to 28V DC

 

No. of sounder circuits

Thee 21 t0 28V DC

 2 X first stage, 1 X second stage

 

 

Packaging & Shipping

 

 

 

 

 

Shpping :by sea .

Our Services

 

 Our services

1.OEM ODM can be provided .

2.Technical support like how to install operate .Any question will be answer within 24 hours .

3.We have prfessional technical team to help customers solve technical problems .

4.Hotel project hospital factory fire alarm system project can be made .

 