Heigh-yield
*Real Time precise MPPT algorithm for max power generation
*Wide input voltage operateion range
*Independent dual MPPT tracking, flexible solar roof system design
Intelligent grid management
*Reactive power capbility
*Limits AC output when grid grequency is too high or to low
*Limits AC outpout when grid voltage is too high
*Built in zero expoert function (optional)
Multiple working modes
*PV & stroage all in one, increases self consumption to 80%+,decreases reliance on the electrical grid, decreases the electricity bill.
*Stand alone mode (like UPS) avaliable, ensures safe operation of critical loads
*Multiple operation modes selection: auto mode, time-of-use mode,timing mode, passive mode etc.
Reliable and Safe
*High efficiency low energy loss, Low maintenance
*High frequency isolation between battery & PV/grid
*Advanced battery management technology to protect the battery life
Easier Operation
*Free site selection due to IP65
*4'LCD clear,easy-to-read display
*Real Time Monitoring

Model   | HYD 3000-ES  | HYD 3600-ES  | HYD 4000-ES  | HYD 5000-ES  | HYD 6000-ES  | |||||
DC Input(PV Side)  | ||||||||||
Max DC input Power  | 3500W  | 4000W  | 4400W  | 5500W  | 6600W  | |||||
Max DC input Voltage  | 600V  | 600V  | 600V  | |||||||
Max DC Input Voltage  | 600VDC  | |||||||||
Start-up Input Voltage  | 120VDC  | |||||||||
Rated Input Voltage  | 360VDC  | |||||||||
MPPT Voltage Range   | 90-580V  | |||||||||
Number of MPPT  | 2  | |||||||||
Max Input Current per MPPT  | 12A/12A  | |||||||||
Battery Parameters  | ||||||||||
Battery Type  | Lithium-ion,Lead-acid  | |||||||||
Nominal battery Voltage  | 48VDC  | |||||||||
Battery voltage range  | 42-58VDC  | |||||||||
Battery Capacity  | 50-2000Ah  | |||||||||
Maximum Charging / Power Discharging  | 3000W  | |||||||||
Maximum Charging Current  | 60A (programmable)  | |||||||||
Maximum Discharging Current  | 60A (programmable)  | |||||||||
Charging curve(Lithium-ion)  | 3-stage adaptive with maintenance  | |||||||||
AC Output(Grid Side)  | ||||||||||
Rated Power  | 3000W  | 3680W  | 4000W  | 5000W  | 6000W  | |||||
Norminal Grid Voltage  | Single phase  L/N/PE, 220-240VAC  | |||||||||
Grid Voltage Range  | 180~276VAC (According to local standard)  | |||||||||
Norminal Frequency  | 50/60HZ  | |||||||||
Grid Frequency Range  | 47-55/54-66HZ (According to local standard)  | |||||||||
Max Input/Output Current  | 13.7A  | 16A  | 18.2A  | 22.8A  | 27.3A  | |||||
THDI  | <3%  | |||||||||
Power Factor  | 1 default(+/-0.8 adjustable)  | |||||||||
Output AC(Emergency Power Supply)  | ||||||||||
EPS rated power  | 3000VA  | |||||||||
Operation Phase  | Single Phase  | |||||||||
EPS rated voltage,Frequency  | 230V, 50/60HZ  | |||||||||
EPS rated current  | 13A  | |||||||||
Peak Output Apparent Power  | 4000VA, 10S  | |||||||||
THDI  | <3%  | |||||||||
Switch time  | 5S Default  (1-60S adjustable)  | |||||||||
Others  | ||||||||||
MPPT Efficiency   | 99.9%  | |||||||||
Protection Degree   | IP65  | |||||||||
PV Reverse Polarity Protection  | YES  | |||||||||
PV insulation detection  | YES  | |||||||||
Ground fault monitoring  | YES  | |||||||||
Over current protection  | YES  | |||||||||
Over voltage protection  | YES  | |||||||||
Battery soft start protection  | YES  | |||||||||
Communication Interface   | RS485,Wi-Fi/GPRS,SD,CAN2.0  | |||||||||
Weight  | 20.5KG  | |||||||||
Dimension  | 566*394*173mm  | |||||||||
Display  | LCD Display  | |||||||||
Certification  | NB/T32004-2013,AS4777,IEC62116,VDE0126-1G83/2,G59/3,EN50438,VDE-AR-N4105  | |||||||||




Professional Packing: Carton, Wooden Pallet and Wooden Box.  | ||||||
By Express  | TNT, DHL, FedDex, UPS available  | |||||
By Air  | Shenzhen/Shanghai or other Designated Airport  | |||||
By Sea  | Shenzhen, Shanghai, Ningbo or other Designated Port in China  | |||||

20KW Home Solar System In Poland