- Place of Origin:
- Zhejiang, China
- Brand Name:
- SAIPWELL
- Model Number:
- 1099-A-117
- Type:
- Electrical Plug
- Grounding:
- GFCI
- Rated Voltage:
- 110V/220V
- Rated Current:
- 15A
- Application:
- Industrial
- OEM/ODM:
- Acceptable
- Voltage 220V:
- Acceptable
- Wire:
- 18AWG-12AWG
- Supply Ability:
- 50000 Piece/Pieces per Month
- Packaging Details
- STARDARD EXPORT PACKING
- Port
- SHANGHAI/NINGBO
GROUND FAULT CIRCUIT INTERRUPTER GFCI ELECTRICAL PLUGS & SOCKETS
GROUND FAULT CIRCUIT INTERRUPTER GFCI ELECTRICAL PLUGS & SOCKETS
Specifications:
1. Rated Supply Voltage(Un): 125V/60Hz/AC
2. Supply Voltage Range: 102V-132V AC
3. Range Current(In): 10mAps-25AMPS
4. Ground Trip Current(In): 4mA-6mA,30mA;
5. Trip Time(T): when In=6mA,T≤0.1s ; when In=264mA,T≤0.025s
6. Withstanding voltage: 1500V AC
7. Withstanding Surge Voltage: 6000V
8. Endurance operations: more than 3000 operations
9. Operating Temperature(TM): -35°c~66°c
10. Relative humidity of the environment(RH): When environment temperarure 25°C,lower than 93%
11. The product possesses rain-proof ability
12. Reset automatically while inserting the power(Put through the load power); Trip automarically when the
power is unusual and on the low side in voltage (Disconnection load power);
13. Controller: 102x45x75mm
14. Other indexes accord with UL 943 standard demand
Application Fields:
1) Belongs to the class I portable electrical equipment and hand-held power tools (Class Ielectrical products, product protection against electric shock not only rely on basic insulation of the equipment, but also contains an additional safety precautions, such asshell ground);
(2) The installation of electrical equipment in wet, corrosive and other harsh places;
(3) The electrical construction machinery and equipment on the construction site;
(4) Temporary a temporary electricity electrical equipment;
(5) socket circuit within the rooms of hotels, restaurants and guest houses;
(6) The socket circuit within the agencies, schools, businesses, and residential buildings;
(7) Swimming pool, fountains and lighting equipment in the water bath;
(8) The mounted in the water supply lines and equipment;
(9) In direct contact with the body"s electrical medical equipment in the hospital;
(10) Other place to install leakage protection.
GROUND FAULT CIRCUIT INTERRUPTER GFCI ELECTRICAL PLUGS & SOCKETS
BIG CURRENT CFCI ELECTRIC PLUGS & SOCKETS
GROUND FAULT CIRCUIT INTERRUPTER GFCI ELECTRICAL PLUGS & SOCKETS
GROUND FAULT CIRCUIT INTERRUPTER GFCI ELECTRICAL PLUGS & SOCKETS
GROUND FAULT CIRCUIT INTERRUPTER GFCI ELECTRICAL PLUGS & SOCKETS
BIG CURRENT CFCI ELECTRIC PLUGS & SOCKETS