Homepage|Business Center|Save the Page|Get the App
普通会员

Shenzhen Richroc Electronic Co., Ltd.

Product Category
  • No Category Yet
Search
 
Link
  • No links
Home > Products > Mini pos machine 12V 2A ups battery
Mini pos machine 12V 2A ups battery
Click on the image to view the original image
Product: views:14Mini pos machine 12V 2A ups battery 
Branch: WGP
Type: On-line
Unit Price: Negotiated
Min.Order:
Supply:
Delivery: Shipment within days since the date of payment
Valid until: Long Term
Updated on: 2019-10-16 18:49
  Negotiated
Product Details
Overview
Quick Details
Place of Origin:
China
Brand Name:
WGP
Model Number:
UPS1202A-15
Phase:
Single Phase
Protection:
over(dis)charged over-current overvoltage and short-circuit protection
Weight:
198g
Output Voltage:
12V 2000mA
Type:
On-line
Application:
standby power
Capacity:
22.2wh 2000mAh
Battery Type:
Lithium Battery
Size:
111*60*26mm
Input Voltage:
12V 2000mA
Backup time:
2~8hours
Model:
UPS1202A-15
Color:
Black
Certification:
CE FCC RoSH PSE
Material:
ABS
Products:
pos machine use ups battery
Supply Ability
Supply Ability:
5000 Piece/Pieces per Week
Packaging & Delivery
Packaging Details
1. 230g/set
2.44pcs/ctn
3. 42-23*24cm
4. 10.98kg/CTN
Port
Shenzhen
Lead Time:
Shipped in 7 days after payment

Mini pos machine 12V 2A ups battery 

 

Product Description

  12V UPS battery is a standby energy storage power supply. Used safe and environmental lithium cells, credible and stable PCB, trickle/constant-current/ constant-voltage lithium battery charging BMS.

  Created by high performance and efficiency DC-DC, boosting and switching circuit. This mini UPS with perfect over-charged, over-discharged, over-current and short-circuit protection.

Features

· 12V UPS battery   

· Over-charged, over-discharged

· Over-current and short-circuit protection

· Private mode in ups

· We have our own PCBA Dept.

· 7 years experienced R&D team

· High Quality:CE,FCC,RoHS,PSE

 

 

Specifications

 

No.ItemTechnical RequirementsRemark
1Input voltage12 ± 5% 
2Input current350mA + loading current 
3Charging current350mA ± 10% 
4Charging transfer efficiency>=75% 
5No-load voltage range12 ± 5% 
6Output current range<=1000mA 
7Output voltage range12 ± 5% 
8Discharging transfer efficiency>=85% 
9Over-discharged protection (battery)6.0VOver-discharged release 6.3v
10Over-charged protection (battery)8.5VOver-charged release 8.25v
11With load current (battery)>=2000mA 

 

Application

    Smart 12V mini ups widely use for fingerprint attendance machine, Fire safety system, security monitoring system, wireless camera, CCTV camera ,personal treatment system,Door security system, personal data assistant, emergency lighting, Alarm system, personal communication systems, radio, digital cameras, camcorders, video camera, Bluetooth devices, CD players, MD players, portable DVD, MP3 players, smart cards. 

 

 

 

  

 

Product Exhibition

 

 

 

 

Company Information

    Shenzhen Richroc Electronic Co.,Ltd.is a professional manufacturer of mini UPS, solar power systems and temperature control battery pack.They are widely used for CCTV camera,mobile phone,notebook computer,PSP,PDA,MP3/4/5,digital camera,LED lamp, DVD/CD player, ADSL modem and router etc.

    Richroc was established in 2009.We have 7 engineers working in this filed for 4-8 years.More than 2 new products are designed forevery month.We have our own brand name WGP.OEM and ODM orders are welcomed. Our products have passed FCC,RoHS,CE and PSE Certificates.The production capacity is 3000 sets per day at least.Our sincerely service,competitive price and fast shipping time are the reasons to choose us.

   

   

FAQ

 

Q:What"s the type of ups?

A:It"s a mini on-line ups.

 

Q:How is it work?
A:When have electricity,ups act as a bridge, city power provide electric to device,at the same time,ups is being charging.When no electricity,then ups back up the device.

 

Q:How to charge the UPS?
A:Battery will only charge with power switch in the ON position.

 

Q:What"s the backup time?How can i decide which model is suitable to my device?
A:Different capacity will have different backup time,with following information,we can choose the most suitable ups to you :
1.What"s the device you plan to use?
2.What"s the working voltage and current?
3.What"s your expected backup time?

 

Q:How can I maintain the device lifetime?
A:When stored, the ups will self-discharge at a rate that is greatly affected by the ambient temperature. It should therefore be fully charged before being put into storage and if it is to be stored for a long period, it should be recharged periodically to prevent it from losing its original capacity. 
As a guide, the ups should not be stored for longer than the periods shown below without being recharged:
6 months at 20°C
3 months at 30°C
2 months at 35°C
If the ups was not used for long time, it is suggested to charge it once every 3~5months

 

Notice:More questions,please contact with me right now,we will choose the right model to you!

Contact US

Sales Manager

Zita Huang

SHENZHEN RICHROC ELECTRONIC CO.,LTD
|| Mobile/whatsapp: + 86-18688744282          || Tel: + 86-755-2712 6881     
|| Web:www.chinarichroc.com                         || http://richroc.en.alibaba.com
|| Skype: chinarichroc                                    || Gmail: zitahuang1(at)gmail.com   
|| Mail: zita.huang (at)chinarichroc.com;  info (at)chinarichroc.com
|| QQ:2355726971                                         || Wechat:Richroc-2010

询价单
total0items  Comments