Product Description


Smart Monitoring System

Technical Specifications
DNS Series(Single Phase)  | GD3000D-NS  | GD3600D-NS  | GD4200D-NS  | GD5000D-NS  | GD6000D-NS  | |||||
PV String Input Data  | ||||||||||
Max.DC Input Power(W)  | 3900  | 4680  | 5460  | 6500  | 7200  | |||||
Max.DC Input Voltage(V)  | 600  | 600 
 | 600 
 | 600 
 | 600 
 | |||||
MPPT Range(V)  | 80~550  | 80~550  | 80~550  | 80~550  | 80~550  | |||||
Start-up Voltage(V)  | 120  | 120  | 120  | 120  | 120  | |||||
Nominal DC Input Voltage(V)  | 360  | 360  | 360  | 360  | 360  | |||||
Max. Input Current(A)  | 11/11  | 11/11  | 11/11  | 11/11  | 11/11  | |||||
Max. Short Current(A)  | 13.8/13.8  | 13.8/13.8  | 13.8/13.8  | 13.8/13.8  | 13.8/13.8  | |||||
No. of MPP Trackers  | 2  | 2  | 2  | 2  | 2  | |||||
No. of Input Strings per Tracker  | 1  | 1  | 1  | 1  | 1  | |||||
AC Output Data  | ||||||||||
Nominal Output Power(W)  | 3000*1  | 3680*1  | 4200*1  | 5000*1  | 6000*1  | |||||
Max. Output Apparent Power(VA)  | 3000  | 3680  | 4200  | 5000  | 6000  | |||||
Nominal Output Voltage(V)  | 220/230  | 220/230  | 220/230  | 220/230  | 220/230  | |||||
Nominal Output Frequency(Hz)  | 50/60  | 50/60  | 50/60  | 50/60  | 50/60  | |||||
Max. Output Currrent(A)  | 13.6  | 16  | 19  | 22.8  | 27.3  | |||||
Max. AC Currrent(A)  | 12  | 14  | 15  | |||||||
Output Power Factor  | ~1(Adjustable from 0.8 leading to 0.8lagging)  | |||||||||
Output THDi(@Nominal Output)  | <3%  | |||||||||
Efficiency  | ||||||||||
Max. Efficiency  | 97.8%  | 97.8%  | 97.8%  | 97.8%  | 97.8%  | |||||
European Efficiency  | 97.5%  | 97.5%  | 97.5%  | 97.5%  | 97.5%  | |||||
Protection  | ||||||||||
Anti-islanding Protection  | Integrated  | Integrated  | Integrated  | Integrated  | Integrated  | |||||
Input Reverse Polarity Protection  | Integrated  | Integrated  | Integrated  | Integrated  | Integrated  | |||||
Insulation Resistor Detection  | Integrated  | Integrated  | Integrated  | Integrated  | Integrated  | |||||
Residual Current Monitoring Unit  | Integrated  | Integrated  | Integrated  | Integrated  | Integrated  | |||||
Output Over Current Protection  | Integrated  | Integrated  | Integrated  | Integrated  | Integrated  | |||||
Output Short Protection  | Integrated  | Integrated  | Integrated  | Integrated  | Integrated  | |||||
Output Over Voltage Protection  | Integrated  | Integrated  | Integrated  | Integrated  | Integrated  | |||||
General Data  | ||||||||||
Operating Temperature Range(°C)  | -25~60  | -25~60  | -25~60  | -25~60  | -25~60  | |||||
Relative Humidity  | 0~100%  | 0~100%  | 0~100%  | 0~100%  | 0~100%  | |||||
Operating Alititude(m)  | ≤4000  | ≤4000  | ≤4000  | ≤4000  | ≤4000  | |||||
Cooling  | Natural Convection  | |||||||||
Noise(dB)  | <25  | <25  | <25  | <25  | <25  | |||||
User Interface  | LCD&LED  | LCD&LED  | LCD&LED  | LCD&LED  | LCD&LED  | |||||
Communication  | RS485 or WiFi or LAN  | |||||||||
Weight(KG)  | 13  | 13  | 13  | 13  | 13.5  | |||||
Size(Width*Height*Depth mm)  | 354*433*147  | |||||||||
Protection Degree  | IP65  | IP65  | IP65  | IP65  | IP65  | |||||
Night self Consumption(W)  | <1  | <1  | <1  | <1  | <1  | |||||
Topology  | Transformerless  | |||||||||
Certifications & Standards  | ||||||||||
Grid Regulation  | VDE-AR-N 4105, VDE0126-1-1, EN50438(PL),EN50438(SW),AS4777.2,IEC61727,IEC62116,CEI 0-21,RD 1669:2011,UNE 206006 IN:2011,UNE 206007-1 IN:2013,G83  | VDE-AR-N 4105, VDE0126-1-1, EN50438(PL),EN50438(SW),AS4777.2,IEC61727,IEC62116,CEI 0-21,RD 1669:2011,UNE 206006 IN:2011,UNE 206007-1 IN:2013,G59  | VDE-AR-N 4105, VDE0126-1-1, EN50438(PL),EN50438(SW),AS4777.2,IEC61727,IEC62116,CEI 0-21,RD 1669:2011,UNE 206006 IN:2011,UNE 206007-1 IN:2013,G59,MEA,PEA  | VDE-AR-N 4105, VDE0126-1-1, EN50438(PL),EN50438(SW),AS4777.2,IEC61727,IEC62116,G59,MEA,PEA  | ||||||
Safety Regulation  | IEC62109-1&-2  | |||||||||
EMC  | EN61000-6-1,EN61000-6-2,EN61000-6-3,EN61000-6-4,EN61000-6-4-16, EN61000-6-18,EN61000-6-29  | |||||||||
*1 For CEI 0-21 Nominal Output Power GW3000D-NS is 2700,GW3680D-NS is 3350,GW4200D-NS is 3800,GW5000D-NS is 4540,GW6000D-NS is 5450.For AS4777,Nominal Output Power GW5000D-NS is 4999.
Details Images & Packing

Our Projects


Our Factory


Request Complete System