Ricoda generator set manufacturers for everyone to introduce, diesel generator radiator how to maintain? First, the diesel generator radiator, maintenance cycle for every 500 hours of operation.
1. External cleaning: (add detergent) with hot water spray and methods from the radiator fan direction before face spray (such as from the opposite direction injection will only dirt approximation center), using this method, to use tape block diesel generator, if the above method does not remove stubborn sediments, should put the radiator removed to soak in a hot alkaline in about 20 minutes, then wash with hot water.
2. Internal descaling:
(1)Drain the water from the radiator, and then the radiator and the pipe connected to the place and closed;
(2) Pour 45 degrees into the radiator of 4% of the acid solution, after 15 minutes dry acid solution, check the radiator;
(3) The groove still has scale, then with 8% of the acid solution to wash again;
(4) After descaling with 3% of the alkali solution neutralization twice, and then rinse three times or more with clean water;
5. After all the work is completed, check whether the radiator leaks, and apply for external repair if it leaks;
6. If no water leakage is re-installed, the radiator should be re-filled with clean water and add rust inhibitor.