rechargeable emergency lights led panel light led downlight ul-usa CEC TITLE20 emergency driver inverter emergency light battery

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Lights & Lighting
  • Validity Period:

    Long Term

  • Published on:

    2021-01-06 12:01

Other Products
Fixtures IP65 rate waterproof lights led strip linear tri-proof linear tri-proof batten triproof
¥Negotiable 27Views

Fixtures IP65 rate waterproo

Recommend  
famous brand driver with good quality  IP54 LED linear Trunk system  light 150lm/w with 5 years warranty
¥Negotiable 27Views

famous brand driver with goo

Recommend  
LED project light with IP54  Aluminum profile led linear trunking lighting system led linear light 68w-72w with big brand driver
¥Negotiable 18Views

LED project light with IP54

Recommend  
IP54 LED linear light 150lm/w for the industrial project solution
¥Negotiable 17Views

IP54 LED linear light 150lm/

Recommend  
China hot sale luxury custom emergency power driver led emergency driver kit 40W dimmable led driver in low price
¥Negotiable 15Views

China hot sale luxury custom

Recommend  
You may like
  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Product Description

 

EMA series emergency drive is UL listed led emergency driver for Field and factory installation that allows

the same led fixture to be used for both normal and emergency operation.In the event of a power failuere.
The emergency driver switches to emergency mode and operates the existing fixture to 90 minutes.
The unit contains a battery charge,and converter for individual fixture requirements.This module will
opeate an LED array load at 15w,25w,40w with constant power at a rated output voltage of 170VDC.
The patented constant power design of the module maintians the output wattage to LED array even as
the system voltage diminished resaulting in a constant illumination level for entire emergency runtime.
The integrated self-diagnostic circuitry will automatically conduct 1 monthly 30- seconds and annual
90-minute tests to verify proper emergency capability per Life Safety Code requirements.
Ordering Information:
        Model   Voltage input     Output power       Output voltage    Emergency time
    EMA25ACT-170
    100-347V          25W         170vdc(120Vac)        90 mins
1.Optimized for higher voltage LED luminaires with 170VDC driver output.
2.High Effciency Performance meets CEC
3.effciency standards (CEC-400-2014-009-CMF).
4.Increased illumination output designed for elevated fxtures
5.UL Listed for factory and feld installation
6.Self-sensing output voltage operates various
7.product types reducing product SKUs for emergency options.
8.backlit panel emergency driver solution
9.UL CUL BC TITLE20 CEC CERTIFICATE
10.Microw inventer emergency driver 
Input Characteristics:
Parameter
Min.
Typical
Max.
Remarks
Rated Input Voltage (Vac)
100
--
347  
Input Voltage Range (Vac)
90
--
380  
Input Frequency Range (Hz)
 47  50/60  63  
Max. Input Current(A)
 --  --  0.2  120Vac, charging
 Max. Input Power(W)  -- --  12  120Vac, charging
 Input Surge Current(A)  --  --  10  347Vac/60Hz, cold start
 Standby Power (W)  --  --  0.8  347Vac/60Hz, charged
 Power Factor  0.85  --  --  Vin=120Vac/60Hz (charging)
 THDI  --  15%  20%  Vin=120-277Vac/60Hz
(charging)
 Max. Load(W)  --  --  250  Max. input power of LED
fixture. And dimming to Min.
input power(before dimming
to off) of LED fixture must be
less than 25W.
 Output Characteristics:
Parameter
Min.
Typical
Max.
Remarks
No Load Output Voltage (Vdc)
--
--
250  
Emergency Output Power (W)
--
--
18
Max. output power limited to 30W
Instantaneous Output Power (W)
-- --
 --
Emergency, cold start peak output, last time 10 seconds
Power-up Time (S)
--
--
3
120Vac, charging
Response Time (S)
--
--
3
Switch from mains supply cuts to Emergency output
Emergency Duration Time
90
--
--
 
Output Voltage (Vdc)
 25  --  230  approximate value, varies with the battery voltage
 Safety Regulation:
Certificate
Approval
Marks
Standard
Valid
Remarks
UL
UL924
YES
North America
cUL
CAN/CSA-C22.2 NO. 141
YES
Canada
BC
CEC Title 20
YES
California
FCC  
FCC
YES
North America
DIMENSION:
Case- 12.36'' X2.28''X1.5 ''(314mmX58mm X38mm)
Mounting Center-11.8''(300mm)
Flexible Conduit 13''(330mm)
Case length 314mm
Case Height 38mm
Case Width 58mm
Mounting lenght 330mm


WIRING DIAGRAM:

1. Normal solution :When the led driver power less than the emergency power

5. With Sensor

Caution:
During AC operation, remember no touch or remove any wires in case of electric shock.
During emergency operation, before touching and disconnecting the wires, remember to
press the test button again to make the led lamp and indicator light off to avoid electric shock .
For the emergency led driver 15w work with LED lamp not more than 15w no need dimmable
function, and more than 15w need the dimmable function .The same as 25w and 40w. 
The voltage input to thedimmable wires(DIM+,DIM-) of emergency LED drivermust less than 20Vdc.
For the emergency led driver 15w better work with LED lamp not more than 80w,for the
25w emergency led driver better work with led lamp not more than 150w ,for the 40w EM driver
must work with led lamp not more than 300w.

SELF-Diagnostic:

The integrated self-diagnostic circuitry will automatically conduct monthly 30-second and annual

90-minute tests to verify proper emergency capability per Life Safety Code requirements.

Press the test button to the emergency mode with 30seconds, after 30seconds the fixtures turn
into the AC mode automatically,when the emergency mode,press the test button turn off the
emergency mode, then can disconnect the wire between emergency driver and fixtures .
NFPA101, Life Safety Code outlines the following schedule:

Monthly - Insure that the test button light is illuminated. Conduct a 30 second discharge test by

depressing the test button.The LED load should operate at reduced output.

Annually - Insure that the test button is illuminated. Conduct a full 90 minute discharge test.

The unit should operate as into endedfor the duration of the test.“Written records of the testing

shall be kept by the owner for inspection by the authority having jurisdiction.”

 

Packaging & Shipping

 

Our Services

 

1.we provide our professsional engineer serivice for our clients.
2. we can do the sample test and dialux ect 
3.label color OEM design 

 

Company Information

 

Company Profile

 
Send your message to this supplier
* Inquiry Title
* Content
* E-mail
* Security Question

Customer Reviews total 0 items

For product pricing, customiztion, or other inquiries

Contact Supplier

Links