Ultrasound Medical Equipment C-90 3.0 4D Ultrasound Machine
1. Main Features
| Computer Specs | Window Embedded operation system (EN language), 19"" medical monitor(1280*1024) + 10.4"" touch monitor, Intel i5 processor, 4G RAM, 120G SSD + 500G HDD |
| Imaging Modes | 2D/3D/ 4D, Color/PW/CW/Power/Directional Color Power Doppler,Tissue Doppler, Color M-Mode, Free Steering (Anatomical) M-Mode |
| Features | Compound Imaging, Speckle Reduction Imaging,Tissue Harmonics Imaging, 4D Real-time,Automatic Image Optimization, Tissue Doppler,Image optimization, Multi-Bean, IMT, Trapezoidal imaging,iBank database. |
| DICOM Modes | Store, Print, Working list, Storage Commitment, Structured Reports |
| Export Options | DICOM, Ethernet, JPG/BMP/PNG,AVI,Network Storage, USB Memory Stick, USB DVD/CD+R(W) |
| Input/Output | VGA, 2 USB Ports, Ethernet, Dicom, Built-in speakers |
| Transducer Types | Convex, Linear, Sector Phased, Micro Convex, 4D Volume Convex, Endocavity, Veterinary linear |
| Applications | Abdominal, OB/GYN, Urology, Cardiac, Vascular, Small Parts, Pediatric, MSK |
| Probe Ports | 4 Active |
| Cine Memory | >10 seconds, 750frames |

2.Probe Specification
| Convex probe-Adult abdomen applicaton | Frequency: 2.5, 3, 3.5, 4, H4, H5MHz Power:5-100% (arithmetic progression of 5:5,10,15...100) Gain:0-100 Dynamic range: 20-280% (geometric progression of 2 start from 20: 20,40,60...280) Gray map:0-7 Frame correlation:0-4 Filtering:0-4 Image denoising:0-14 Scanning depth:3-27.3cm Body mark:17 Scanning range:50-100% (arithmetic progression of 10 start from 50: 50,60,70...100) Focus point:6 Pseudo color map :0-11 Linear density:64,128,256 TSI: normal, fat, fluid, muscle Reversal:up/down, left/right Compound frequency: on/off Automatic optimization: on/off Space compound: on/off |
| Linear Probe-Carotid Application | Frequency: 6, 7.5, 8.5, 10, H10 MHz Power:5-100% (arithmetic progression of 5: 5,10,15...100) Gain:0-100 Dynamic range: 20-280% (geometric progression of 2 start from 20: 20,40,60...280) Gray map:0-7 Frame correlation:0-4 Filtering:0-4 Image denoising:0-14 Scanning depth:2-11cm Body mark:13 Scanning range:50-100% (arithmetic progression of 10 start from 50: 50,60,70...100) Focus point:5 Pseudo color map :0-11 Linear density:64,128,256 TSI: normal, fat, fluid, muscle Reversal:up/down, left/right Steering: left/right Trapezoid Imaging: on/off Compound frequency: on/off Automatic optimization: on/off Space compound: on/off |
| Cardiac Probe - Adult cardiac application | Frequency: 2.5, 3, 3.5, 4, H3, H4 MHz Power:5-100% (arithmetic progression of 5: 5,10,15...100) Gain:0-100 Dynamic range: 20-280% (geometric progression of 2 start from 20: 20,40,60...280) Gray map:0-7 Frame correlation:0-4 Filtering:0-4 Image denoising:0-14 Scanning depth:3-27.3cm Body mark:7 Scanning range:50-100% (arithmetic progression of 10 start from 50: 50,60,70...100) Focus point: 5 Pseudo color map :0-11 Linear density:64,128,256 TSI: normal, fat, fluid, muscle Reversal:up/down, left/right Compound frequency: on/off Automatic optimization: on/off Space compound: on/off |
| 4D Probe - Obstetrics application | Frequency: 2, 3, 4.5, 6, H5 MHz Power:5-100% (arithmetic progression of 5: 5,10,15...100) Gain:0-100 Dynamic range: 20-280% (geometric progression of 2 Frame correlation:0-4 Filtering:0-4 Image denoising:0-14 Scanning depth:3-27.3cm Body mark:7 Scanning range:50-100% (arithmetic progression of 10 start from 50: 50,60,70...100) Focus point: 6 Pseudo color map :0-11 Linear density:64,128,256 TSI: normal, fat, fluid, muscle Reversal:up/down, left/right Compound frequency: on/off Automatic optimization: on/off Space compound: on/off |



3.C-90 3.0V The probe frequency
Pediatrics micro-convex C5-9R10:
Middle frequency 7.0MHz
Frequency conversion:H8.0, 9.0, 7.0, 6.0, 4.5MHz
Micro-convex C25R20:
c5.0MHz
Frequency conversion:H5.0, H4.0, 5.0, 4.0, 3.5, 2.0MHz
4D probe R40
Middle frequency :H5.0MHz
Frequency conversion:3.0, H5.0, 6.0, 4.5, 3.0, 2.0MHz