Product Details
- Place of Origin:
- Guangdong, China
- Brand Name:
- ASENWARE
- Model Number:
- AW-CFP2166 series
- Item:
- 1-32 Zone Conventional Fire Alarm With Smoke Alarm
- Mains supply voltage:
- 110VAC or 240VAC
- Internal power supply:
- 27.2VDC
- Total output current limited:
- 3A @ 240VAC
- Main supply monitor for fault:
- yes
- Battery protection for low voltage:
- yes
- Payment:
- T/T,WESTERN UNION
- Line fault monitor for open circuit:
- yes
- Line fault monitor for short circuit:
- yes
- Number of general circuits:
- 2
- Supply Ability:
- 10000 Piece/Pieces per Month
- Packaging Details
- opp packed or as customized for Fire Detection EquipmentPanel
- Port
- Shenzhen or Hongkong
1-32 Zone Conventional Fire Alarm With Smoke Alarm

Overview
1. AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2. It is modularized design, the panel can extend from 1 zone to 32 zones easily.
3. It has 2 level control mode by a lockIt has 24VDC and 5VDC power supply output.
4. It has FIRE and FAULT signal output.
5. It has 2 general sounders output.
6. Each zone has 1 circuit detectors input .
7. Each zone can be disable by a button.
8. It has RESET button to reset the panel.
9. It has SILENCE button to stop BUZZER and SOUNDERS.
10. It has EVACUATE button to start a manual fire alarm immediately.
11. It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
12. It has an optional GSM module for fire alarm by SMS .
13. It is economic, user-friendly and easy maintenance.
Parameter
Model | Conventional Fire Alarm Panel AW-CFP2166 (1-32 Zone) |
Matched | Conventional Smoke Detector/Heat Detector/Manual Call Point Fire alarm bell/Strobe horn/Flash light |
Working Environment | industrial and civil buildingsrestaurants, hotels, teaching buildings, office buildings, computer rooms, communication machine rooms, |
Benefits | wiring your building into different zones, economical |
ITEM | 1Zone panel | 2Zone panel | 4-8 Zone panel | 12-32 Zone panel |
Model No. | AW-CFP2166-01 | AW-CFP2166-02 | AW-CFP2166-04-8 | AW-CFP2166-12-32 |
Power specification |
| |||
Mains supply voltage | 110VAC or 240VAC | |||
Internal power supply | 27.2VDC | |||
Total output current limited | 500mA @ 240VAC | 500mA @ 240VAC | 3A @ 240VAC | 3A @ 240VAC |
Main supply monitor for fault | Yes | |||
Battery protection for low voltage | Yes | |||
Batteries (default configuration) | 12V2AH*2 | |||
Detector circuit specification |
| |||
Number of circuit | 1 | 2 | 4-16 | 4-32 |
Line fault monitor for open circuit | Yes | |||
Line fault monitor for short circuit | Yes | |||
Line fault monitor for detector removal | Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor | |||
End of Line device | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) | |||
Detector continuity diodes | Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault) | |||
Call point resistor value | 470 to 680 Ω, 0.225 or 0.5 watt | |||
Maximum number of smoke/heat detectors per zone | 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts. | |||
Maximum number of manual call points per zone | No limit | |||
Sounder circuit specification |
| |||
Number of general circuits | 2 | |||
End of line resistor value | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) | |||
Line fault monitor for open circuit | Yes | |||
Line fault monitor for short circuit | Yes | |||
Outputs fused AT | 400mA | |||
Maximum number of bells @ 20mA of each sounder output | 20 | |||
Fuses |
| |||
Battery fuse | 1.5A F 20mm | |||
Sounder outputs | 500mA F 20mm | |||
Fire and fault output |
| |||
Output type | NC and NO relay | |||
Maximum current | 100mA | |||
Connection block |
| |||
Largest acceptable conductor size | 2.5mm2 | |||
Smallest acceptable conductor size | 0.75mm2 | |||
Size and weight |
|
| ||
Dimensions(mm) | 272*200*70mm | 320*231*90mm | 395X502X124 | 362X565X124 |
Weight (without batteries) | 4kg | 5kg | 7kg | 8kg |
Weight (with batteries) | 5.8kg | 6.8kg | 9.6kg | 12.5kg |
Fire Alarm System AW-2166

1.Are you manufacturer?
(yes)
2.How do you package?
(Standard export packing including):
1) PEE bag per unit
2) Outside Cartons
3.what kind of shipment?
4. warranty
(two years)
5.Delivery time
usually
Fire control: one week working day
bulk quality: three weeks working days
Emergency lights: two weeks working days
bulk quality: four weeks
FM200: two weeks working day
Fire pump: 25 days
6. technical support
fire alarm and fire
fighting solutions
provider
our project list
FEW RECENT FINISHED PROJECTS
• Indonesia: Government Apartment ( Addressable and Telephone Panel)
• Cambodia: Coal Plant ( FM-200, LPCO2 System, Addressable Panel )
• Kenya: Senior High School ( Addressable and Conventional Panel)
• Bangladesh: Industrial Building ( Addressable Panel )
• Thailand: Ware House ( Addressable Panel with Beam Detectors )
• Laos: Telecommunication Center ( FM-200, Addressable Panel )