Product Details
- Place of Origin:
- Guangdong, China
- Brand Name:
- Asenware, Asenware
- Model Number:
- AW-CFP2166
- Product Description:
- 220V AC GSM Fire Alarm Control Panel Prices
- Model No.:
- AW-CFP2166
- Executive Standard:
- GB19880-250
- Mains Supply Voltage:
- 110VAC or 240VAC
- Circus Bus:
- 2-wire Bus System
- Fire Output Type:
- NC and NO relay
- Support Service:
- OEM;ODM is welcomed
- Certificates:
- CE;LPCB; ISO9001;Appearance Design Patent Certificate
- Applicable:
- Construction buildings; Home secutiry;Restaurant;Hospital etc.
- Supply Ability:
- 1000000 Piece/Pieces per Year
- Packaging Details
- EPE inside, carton outside.
- Port
- Shenzhen,China
* AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
* It is modularized design, the panel can expend from 1 zone to 32 zones easily.
* It has 2 level control mode by a lock
* It has 24VDC and 5VDC power supply output.
* It has FIRE and FAULT signal output.
* It has 2 general sounders output.
* Each zone has 1 circuit detectors input .
* Each zone can be disable by a button.
* It has RESET button to reset the panel.
* It has SILENCE button to stop BUZZER and SOUNDERS.
* It has EVACUATE button to start a manual fire alarm immediately.
* It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
* It has an optional GSM module for fire alarm by SMS .
* It is economic, user-friendly and easy maintenance.

| ITEM | 1 Zone panel | 2 Zone panel | 4-8 Zone panel | 4-32 Zone panel |
| Model No. | AW-CFP2166-01 | AW-CFP2166-02 | AW-CFP2166-04-08 | AW-CFP2166-04-16 |
| Power Specification | ||||
| Mains supply voltage | 110VAC or 240VAC | |||
| Internal power supply | 27.2VDC | |||
| Total output current limited | 500mA @ 240VAC | 3A @ 240VAC | ||
| Main supply monitor for fault | Yes | |||
| Battery protection for low voltage | Yes | |||
| Batteries (default configuration) | 12V2AH*2 | |||
| Detector Circuit Specification | ||||
| Number of circuit | 1 | 2 | 4-8 | 4-32 |
| Line fault monitor for open circuit | Yes | |||
| Line fault monitor for short circuit | Yes | |||
| Line fault monitor for detector removal | Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor | |||
| End of Line device | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) | |||
| Detector continuity diodes | Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault) | |||
| Call point resistor value | 470 to 680 Ω, 0.225 or 0.5 watt | |||
| Maximum number of smoke/heat detectors per zone | 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts. | |||
| Maximum number of manual call points per zone | No limit | |||
| Sounder Circuit Specification | ||||
| Number of general circuits | 2 | |||
| End of line resistor value | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) | |||
| Line fault monitor for open circuit | Yes | |||
| Line fault monitor for short circuit | Yes | |||
| Outputs fused AT | 400mA | |||
| Maximum number of bells @ 20mA of each Sounder output | 20 | |||
| Fuses | ||||
| Battery fuse | 1.5A F 20mm | |||
| Sounder outputs | 500mA F 20mm | |||
| Fire Output | ||||
| Output type | NC and NO relay | |||
| Maximum current | 100mA | |||
| Connection Block | ||||
| Largest acceptable conductor size | 2.5mm2 | |||
| Smallest acceptable conductor size | 0.75mm2 | |||
| Size and Weight | ||||
| Dimensions(mm) | 272X200X70 | 320X231X90 | 395X502X124 | 362X565X124 |
| Weight (without batteries) | 4kg | 5kg | 7kg | 8kg |
| Weight (with batteries) | 5.8kg | 6.8kg | 19.6kg | 12.5kg |
More Images
2 Zone Panel:

4 Zone Panel:

32 Zone Panel:

Red Look:

Black Look:

System Diagram of The Conventional Fire Alarm Panel

The Whole Fire Alarm Control Panel System
| The conventional fire alarm control system 2166 series match the below detectors and accessories: | |||||||
| Image | ![]() | ||||||
| Name | conventional photoelectric smoke detector | conventional fixed temperature heat detector | conventional smoke and heat combind detector | conventional manual call point/break glass | conventional hooter/horn | conventional fire bell | conventional flash light |
| Model No. | AW-CSD311 | AW-CTD805 | AW-CSH202 | AW-CMC2166-1 AW-CMC2166-5 | AW-CSS2166-2 | AW-CBL2166-A | AW-CBL2166 |
Applicated in Various Places and Environment

Packaging

Shipping

Our services and advantages
* Over 10 years" experience.
* Prompt response.
* OEM & ODM available.
* Support factory inspection.
* Standard qulity control system.
* Different choices of payment and delivery.
* Independant R&D dept, designing dept,to meet your special need.
* Whole set of technical supports and with abroad projects experience.
* We are manufacturer, offer better price better production control.
* Sample order, customized order, bulk order are supported.
* Reliable after-sales service, with one year waranty.


Customers

Contacts
Shenzhen Asenware Test & Control Technology Co.,Ltd.

Just feel free to contact us now, best service and favorable quotation will be offered to you ! !



Share























Customer Reviews total 0 items