Brand: |
none |
Address: |
China |
Min.Order: |
none |
Supply: |
none |
Valid until: |
Long Term |



China
Long Term
2019-10-17 03:16
Scan By Phone



Brand: |
none |
Address: |
China |
Min.Order: |
none |
Supply: |
none |
Valid until: |
Long Term |
100/200/324Addresses Smart Fire Alarm Monitoring System Featured By:
1.A new type of analog smart fire alarm control panel
2.Non-polarity wire connection system
3.Optional 100/200/324 optional addresses
4.Mixed coding + two buses
Based on The Fire Alarm Control Units (GB4717-2005) & Automatic Control System for Fire Protection (GB16806-2006).
2.Function Descriptions:
1) The image of the addressable fire alarm control panel:

2).The characteristics of the addressable fire alarm control panels:
Model No. | AW-AFP2188-100/AW-AFP2188-200/AW-AFP2188-324 |
Data processing | Collect data:through the internal microprocessors in the intelligent detectors and modulesto realize digital filtering and auto-compensation functions; Carry out data: based on fuzzy control theory and modern fire alarm theory to carry out data processing |
Power supply system | an AC-DC master-standby power supply system |
| Support mini-printer |
| Support ten multi-line linkage control/monitoring points to control and monitor important equipment. |
For the users | be equipped with eight bus manual control points, which makes Easy for user sto control related equipment. |
industrial & civil buildings factories, hospitals, restaurants, hotels, schools, business buildings, government buildings,etc. | |
Advantage | Accurate & efficient feedback, Humanized setting, Economic, User-friendly & convenient maintenance,etc. |
3. Main technical parameters
Main technical parameters: | |
AW-AFP2188 system capacity | 100/200/324 points (non-polarity, two wire bus, fully mixed coding) |
AC input voltage | AC 220V±20% 50Hz |
DC power | DC24V 5.0Ah, two fully sealed maintenance-free DC12V 5.0Ah storage batteries connected in series |
AC input power | 120W |
Circuit bus | two-wire system |
Total length | ≤1500m |
Voltage UL of the circuit bus | +20V≤UL≤+26V(when the DC power is operating) +24V≤UL≤+26V(when the AC power is operating) |
System working conditions
| 1. Temperature: -10°C~+50°C 2.Humidity: ≤95% 3.Power supply: AC 220V 50HZ DC 24V 6A 4.Output contact capacity: AC 220V 1A DC 27.6V 3A |
4. The diagram of the addressable fire alarm system:

5.The Whole Diagram of the Fire Alarm Control Panel System

The ex-works configuation of addressable accessories involved:
1) AW-ASD2188:Addressable Photoelectric Smoke Detector
2) AW-ATD2188:Addressable Fixed Temperature Heat Detector
3) AW-AMC2188:Addressable Manual Call Point
4) AW-ASS2188:Addressable Strobe Siren
5) AW-AIO2188-IN:Addressable Input Module
6) AW-AIO2188-OUT:Addressable Out Module
7) AW-CODER2188:Coder for setting addresses.






Keywords:smart fire alarm,fire alarm panel,addressable fire alarm host,fire device,fire equipment,fie alarm system,intelligent fire alarm host,addressable fire alarm factory,addressable fire alarm price,addressable fire alarm manufacturer,smart fire alarm panel,fire alarm solution,addressable fire alarm panel,addressable fire alarm solution,fire security system