Brand: |
none |
Address: |
China |
Min.Order: |
none |
Supply: |
none |
Valid until: |
Long Term |
Product Details
- Place of Origin:
- Guangdong, China
- Brand Name:
- Asenware, Asenware
- Model Number:
- AW-CFP2166-4
- Product Description:
- Model Fire Alarm System Control Panel 4 Fire Relay Outputs
- Executive Standard:
- GB19880-250
- Mains Supply Voltage:
- 110VAC or 240VAC
- Circus Bus:
- 2-wire Bus System
- Fire Output Type:
- NC and NO relay
- Color Option:
- Red; Black; White; Grey; Other customized colors
- Support Service:
- OEM;ODM is welcomed
- Selling Point:
- With fire relay of each zone
- Applicable:
- Construction buildings; Home secutiry;Restaurant;Hospital etc.
- Supply Ability:
- 1000000 Piece/Pieces per Year
- Packaging Details
- EPE inside, carton outside.
- Port
- Shenzhen,China
- Lead Time:
Quantity(Pieces) 1 - 1000 >1000 Est. Time(days) 15 To be negotiated
* AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
* It is modularized design, the panel can expend from 1 zone to 32 zones easily.
* It has 2 level control mode by a lock
* It has 24VDC and 5VDC power supply output.
* It has FIRE and FAULT signal output.
* It has 2 general sounders output.
* Each zone has 1 circuit detectors input .
* Each zone can be disable by a button.
* It has RESET button to reset the panel.
* It has SILENCE button to stop BUZZER and SOUNDERS.
* It has EVACUATE button to start a manual fire alarm immediately.
* It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
* It has an optional GSM module for fire alarm by SMS .
* It is economic, user-friendly and easy maintenance.
fire alarm control panel each zone fire reply output

| ITEM | 1 Zone panel | 2 Zone panel | 4-8 Zone panel | 4-32 Zone panel |
| Model No. | AW-CFP2166-01 | AW-CFP2166-02 | AW-CFP2166-04-08 | AW-CFP2166-04-16 |
| Power Specification | ||||
| Mains supply voltage | 110VAC or 240VAC | |||
| Internal power supply | 27.2VDC | |||
| Total output current limited | 500mA @ 240VAC | 3A @ 240VAC | ||
| Main supply monitor for fault | Yes | |||
| Battery protection for low voltage | Yes | |||
| Batteries (default configuration) | 12V2AH*2 | |||
| Detector Circuit Specification | ||||
| Number of circuit | 1 | 2 | 4-8 | 4-32 |
| Line fault monitor for open circuit | Yes | |||
| Line fault monitor for short circuit | Yes | |||
| Line fault monitor for detector removal | Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor | |||
| End of Line device | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) | |||
| Detector continuity diodes | Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault) | |||
| Call point resistor value | 470 to 680 Ω, 0.225 or 0.5 watt | |||
| Maximum number of smoke/heat detectors per zone | 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts. | |||
| Maximum number of manual call points per zone | No limit | |||
| Sounder Circuit Specification | ||||
| Number of general circuits | 2 | |||
| End of line resistor value | 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold) | |||
| Line fault monitor for open circuit | Yes | |||
| Line fault monitor for short circuit | Yes | |||
| Outputs fused AT | 400mA | |||
| Maximum number of bells @ 20mA of each Sounder output | 20 | |||
| Fuses | ||||
| Battery fuse | 1.5A F 20mm | |||
| Sounder outputs | 500mA F 20mm | |||
| Fire Output | ||||
| Output type | NC and NO relay | |||
| Maximum current | 100mA | |||
| Connection Block | ||||
| Largest acceptable conductor size | 2.5mm2 | |||
| Smallest acceptable conductor size | 0.75mm2 | |||
| Size and Weight | ||||
| Dimensions(mm) | 272X200X70 | 320X231X90 | 395X502X124 | 362X565X124 |
| Weight (without batteries) | 4kg | 5kg | 7kg | 8kg |
| Weight (with batteries) | 5.8kg | 6.8kg | 19.6kg | 12.5kg |
fire alarm control panel each zone fire reply output
More Images




System Diagram of The Conventional Fire Alarm Panel

The Whole Fire Alarm Control Panel System
| The conventional fire alarm control system 2166 series match the below detectors and accessories: | |||||||
| Image | ![]() | ||||||
| Name | conventional photoelectric smoke detector | conventional fixed temperature heat detector | conventional smoke and heat combind detector | conventional manual call point/break glass | conventional hooter/horn | conventional fire bell | conventional flash light |
| Model No. | AW-CSD311 | AW-CTD805 | AW-CSH202 | AW-CMC2166-1 AW-CMC2166-5 | AW-CSS2166-2 | AW-CBL2166-A | AW-CBL2166 |
fire alarm control panel each zone fire reply output
Applicated in Various Places and Environment

fire alarm control panel each zone fire reply output


* Over 10 years" experience.
* Prompt response.
* OEM & ODM available.
* Support factory inspection.
* Standard qulity control system.
* Different choices of payment and delivery.
* Independant R&D dept, designing dept,to meet your special need.
* Whole set of technical supports and with abroad projects experience.
* We are manufacturer, offer better price better production control.
* Sample order, customized order, bulk order are supported.
* Reliable after-sales service, with one year waranty.
fire alarm control panel each zone fire reply output
* Is Asenware Company a factory ?
Yes, we have Factory in Zhongshan, Office in Shenzhen, Headquarter in London.
* What is our payment term ?
T/T; L/C; Western union.
* How long is the delivery time ?
Usually about 2 to 7 days. Mass production about 3 weeks.
* Do we have technical support ?
Yes, we have a professional engineering team.
* How to assure the quality ?
Firstly, all of our materials and components pass the serious China Quality Standard and Control.
Secondly, all of our finished products should pass Asenware Quality Check System before export.
Thirdly, our products can be provided to test and cetify by Authories according to customer"s special need.
* Do we have warranty ?
Yes, One year or more depends.
* Sample for testing ?
Yes, Stock sample or Customized sample is available.
* Procedure to Purchase our products ?
Inquiry --- Offer --- Dicssion --- Confirmation --- Order --- Deposit --- Production --- Payment --- Shipment --- Arrival --- Finished --- Feedback --- Repeat Order.
* The ways to contact us ?
Offical web "asenware.en.alibaba.com"; Domestic and Abroad Exhibitions; Factory Tour; Email & Phone etc.
fire alarm control panel each zone fire reply output
Inquire Now !
with Fire relay of each zone fire alarm system
Zone fire relay output fire alarm control panel
Each zone fire relay fire alarm panel
Each zone fire output security system alarm panel



Share























Customer Reviews total 0 items