Emergency Device Manual Pull Station Fire Alarm

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Lights & Lighting
  • Validity Period:

    Long Term

  • Published on:

    2019-10-17 03:08

Other Products
Intelligent Wireless Addressable fire alarm control panel with Touch Screen
¥Negotiable 40Views

Intelligent Wireless Address

Recommend  
En54 Standards Wireless Addressable fire alarm control panel with GSM Function
¥Negotiable 41Views

En54 Standards Wireless Addr

Recommend  
Addressable Fire Fighting Equipment,Gas Control Panel AW-AFP2188-200 with GSM Module ,3 Series
¥Negotiable 45Views

Addressable Fire Fighting Eq

Recommend  
Conventional Fire Alarm Flash Light //Fire Suppression System
¥Negotiable 44Views

Conventional Fire Alarm Flas

Recommend  
HOT!!! 32 Zone Conventional Gas Release Control Panel AW-CFP2166,Fire Fighting Equipment with GSM Module,FM200
¥Negotiable 47Views

HOT!!! 32 Zone Conventional

Recommend  
You may like
  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
Asenware
Model Number:
AW-CMC2166-6
Product Name:
Emergency Device Manual Pull Station Fire Alarm
Operating Voltage:
9 -28 VDC Volts
Operating Current:
Alarm Current: 45 mA@ 24VDC
Contactor Resistance:
5.6K
Temperature:
-10℃ to 50 ℃
Humidity:
10% to 93%, Non-condensation
Feature:
Resettable
Color:
Red or Customized
Weight:
220g
Wiring Method:
Nonpolar two-bus system
Supply Ability
Supply Ability:
1000 Piece/Pieces per Week
Packaging & Delivery
Packaging Details
Standard export packing including:
1) PP Bag
2) Cartons
3) Pallets or plywood case for sea shipping
Port
Shenzhen; China Ocean Port

 

     Emergency Device Manual Pull Station Fire Alarm 

 

 

 

 

 


 

 

Product Description

 

Description of Manual call point:

 

* The AW-CMC2166-6 Manual Call Point is used to manually transmit fire alarm signal, it provides contact closure to activate emergency equipment, audible and visual signals, and alarm panels.

* It"s designed for conventional fire alarm system for reporting fire or emergency condition by pressing its breakable glass. The manual call point can be test by a test key without breaking the glass.

 

Before Installing of Manual call point:

NOTICE: This manual should be left with the owner/user of this equipment.

 

Operation of Manual call point:

* The mannual push button provide textured finger-hold area that includes braille text. In addtion to push in and pull down text there are arrows indicating how to oprate the station, provide for non english speaking people
* Pushing in and then pulling down on the handle activates the normally open alarm switch. Ocnce latched in the down position the word activated appears at the top in bright yellow with a portion of the handle proturding at the bottom as a visible flag.
* Resetting the station is simple: Insert the key, twist one quarter-turn then open the station"s front cover. Causing the spring-loaded operation handle to return to its orginal position. The alarmn switch can then be reset to its normal position manually or by closing the station"s front cover. Which automatically reset the switch.


Loop Design and Wiring of Manual call point:

* The fire alarm control panel Zone wire can be connected to terminal 2(+), 4(-).
* And there is a 5.1V Zener diode should be connected to terminal 1A and 4A. (included by default).
* If the manual call point is in the end of the zone wire, a 5.6K resistance should be connected to terminal

 

Usage of Manual call point:

* It is generally installed in staircase, hallway, evacuation passage or places where people haunt.

 

Manual call point 

* We have another conventional manual call point which is resettable, "AW-CMC2166-5" and another conventional break glass manual call point which is unresettable "AW-CMC2166-1". More details, pls scearch the Model No. on our officail website or contact me directly.

  

Specification  of Manual call point:

 

Product NameManual Call Point/Resettable
Model No.AW-CMC2166-6
Operating Voltage9 -28 VDC Volts
Operating CurrentAlarm Current: 45mA@24 VDC
Contactor Resistance5.6K
Temperature-10℃ to 50 ℃
Humidity10% to 93%, Non-condensation
FeatureResettable
ColorRed or Customized
Dimension140MM*105mm*45mm
Weight220g
Wiring MethodNonpolar two-bus system
Operating enviromentIndoor
Applicable PlacesSchool;Factory;Office;Dormitory;Super Market etc.

 

 

 

Product Images

 

 

 

 

 

 

 

 

 

 

 

Related Products

 

Fire alarm related products:

 

 

 

 

 

 

 

Our Services

 

 

* Over 10 years" experience.

* Prompt response.

* OEM & ODM is available.

* Support factory inspection.

* Standard qulity control system.

* Different choices of payment and delivery.

* Independant R&D dept, designing dept,to meet your special need.

* Whole set of technical supports and with abroad projects experience.

* We are manufacturer, offer better price better production control.

* Sample order, customized order, bulk order are supported.

* Reliable after-sales service, with one year waranty.

 

 

FAQ

 

 

   conventional smoke detector, smoke sensor,

* Is Asenware Company a factory ?

   Yes, we have Factory in Zhongshan, Office in Shenzhen, Headquarter in London.

 

* What is our payment term ?

   T/T; L/C; Western union.

 

* How long is the delivery time ?

   Usually about 2 to 7 days. Mass production about 3 weeks.

 

* Do we have technical support ?

   Yes, we have a professional engineering team.

 

* How to assure the quality ?

   Firstly, all of our materials and components pass the serious China Quality Standard and Control.

   Secondly, all of our finished products should pass Asenware Quality Check System before export.

   Thirdly, our products can be provided to test and cetify by Authories according to customer"s special need.

 

* Do we have warranty ?

   Yes, One year or more depends.

 

* Sample for testing ?

   Yes, Stock sample or Customized sample is available.

 

* Procedure to Purchase our products ?

   Inquiry --- Offer --- Dicssion --- Confirmation --- Order --- Deposit --- Production --- Payment --- Shipment --- Arrival --- Finished --- Feedback --- Repeat Order.

 

* The ways to contact us ?

   Offical web "asenware.en.alibaba.com"; Domestic and Abroad Exhibitions; Factory Tour; Email & Phone etc.

 

 

 

 

Packaging & Shipping

 

   conventional smoke detector, smoke sensor,

  conventional smoke detector, smoke sensor,

 

Company Information

 

 

 

 

 
   conventional smoke detector, smoke sensor,

 conventional smoke detector, smoke sensor,

 

Just feel free to contact us now, best service and favorable quotation will be offered to you ! !

 

 

break glass , manual call point, unresertable manual call point, fire alarm, fire alarm system

 

 

break glass , manual call point, unresertable manual call point, fire alarm, fire alarm system

Send your message to this supplier
* Inquiry Title
* Content
* E-mail
* Security Question

Customer Reviews total 0 items

For product pricing, customiztion, or other inquiries

Contact Supplier

Links