Fire Fighting Fault Routing Fire Alarm Panel Control System

  • Unit Price: Negotiable
  • Brand:

  • Origin:

    China

  • Categories:Lights & Lighting
  • Validity Period:

    Long Term

  • Published on:

    2019-10-17 03:11

Other Products
Intelligent Wireless Addressable fire alarm control panel with Touch Screen
¥Negotiable 40Views

Intelligent Wireless Address

Recommend  
En54 Standards Wireless Addressable fire alarm control panel with GSM Function
¥Negotiable 40Views

En54 Standards Wireless Addr

Recommend  
Addressable Fire Fighting Equipment,Gas Control Panel AW-AFP2188-200 with GSM Module ,3 Series
¥Negotiable 44Views

Addressable Fire Fighting Eq

Recommend  
Conventional Fire Alarm Flash Light //Fire Suppression System
¥Negotiable 43Views

Conventional Fire Alarm Flas

Recommend  
HOT!!! 32 Zone Conventional Gas Release Control Panel AW-CFP2166,Fire Fighting Equipment with GSM Module,FM200
¥Negotiable 46Views

HOT!!! 32 Zone Conventional

Recommend  
You may like
  • Product Description
  • Company Overview

Product Information

Brand:

none

Address:

China

Min.Order:

none

Supply:

none

Valid until:

Long Term

Product Details

Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
Asenware, Asenware
Model Number:
AW-CFP2166
Product Description:
Fire Fighting Fault Routing Fire Alarm Panel Control System
Model No.:
AW-CFP2166
Executive Standard:
GB19880-250
Mains Supply Voltage:
110VAC or 240VAC
Circus Bus:
2-wire Bus System
Fire Output Type:
NC and NO relay
Support Service:
OEM;ODM is welcomed
Certificates:
CE;LPCB; ISO9001;Appearance Design Patent Certificate
Applicable:
Construction buildings; Home secutiry;Restaurant;Hospital etc.
Supply Ability
Supply Ability:
1000000 Piece/Pieces per Year
Packaging & Delivery
Packaging Details
EPE inside, carton outside.
Port
Shenzhen,China
Fire Fighting Fault Routing Fire Alarm Panel Control System  
 
Introduction and Parameters

 

Product Description

  

* AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.

* It is modularized design, the panel can expend from 1 zone to 32 zones easily.

* It has 2 level control mode by a lock

* It has 24VDC and 5VDC power supply output.

* It has FIRE and FAULT signal output.

* It has 2 general sounders output.

* Each zone has 1 circuit detectors input .

* Each zone can be disable by a button.

* It has RESET button to reset the panel.

* It has SILENCE button to stop BUZZER and SOUNDERS.

* It has EVACUATE button to start a manual fire alarm immediately.

* It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.

* It has an optional GSM module for fire alarm by SMS .

* It is economic, user-friendly and easy maintenance.


 

 

ITEM1 Zone panel2 Zone panel4-8 Zone panel4-32 Zone panel
Model No.AW-CFP2166-01AW-CFP2166-02AW-CFP2166-04-08AW-CFP2166-04-16
Power Specification           
Mains supply voltage110VAC or 240VAC   
Internal power supply27.2VDC   
Total output current limited500mA @ 240VAC 3A @ 240VAC 
Main supply monitor for faultYes   
Battery protection for low voltageYes   
Batteries (default configuration)12V2AH*2   
Detector Circuit Specification    
Number of circuit124-84-32
Line fault monitor for open circuitYes   
Line fault monitor for short circuitYes   
Line fault monitor for detector removalYes, if End of Line Monitor Unit fitted in place of End of Line Resistor   
End of Line device6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)   
Detector continuity diodesSilicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)   
Call point resistor value470 to 680 Ω, 0.225 or 0.5 watt   
Maximum number of smoke/heat detectors per zone20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.   
Maximum number of manual call points per zoneNo limit   
Sounder Circuit Specification    
Number of general circuits2   
End of line resistor value6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)   
Line fault monitor for open circuitYes   
Line fault monitor for short circuitYes   
Outputs fused AT400mA   
Maximum number of bells @ 20mA of each Sounder output20   
Fuses    
Battery fuse1.5A F 20mm   
Sounder outputs500mA F 20mm   
Fire Output    
Output typeNC and NO relay   
Maximum current100mA   
Connection Block    
Largest acceptable conductor size2.5mm2   
Smallest acceptable conductor size0.75mm2   
Size and Weight    
Dimensions(mm)272X200X70320X231X90395X502X124362X565X124
Weight (without batteries)4kg5kg7kg8kg
Weight (with batteries)5.8kg6.8kg19.6kg12.5kg

More Images

2 Zone Panel:

 

4 Zone Panel:

32 Zone Panel:

Red Look:

Black Look:

 

System Diagram of The Conventional Fire Alarm Panel

 

 

 

The Whole Fire Alarm Control Panel System

 

The conventional fire alarm control system 2166 series match the below detectors and accessories:
Image    
Name conventional photoelectric smoke detector conventional fixed temperature heat detector conventional smoke and heat combind detector conventional manual call point/break glass conventional hooter/horn conventional fire bell conventional flash light
Model No. AW-CSD311 AW-CTD805 AW-CSH202

AW-CMC2166-1

AW-CMC2166-5

 AW-CSS2166-2 AW-CBL2166-A AW-CBL2166

 

 

Applicated in Various Places and Environment 

Packaging & Shipping

 

Packaging

 

 

 

Shipping

 

 

Our Services

 

Our services and advantages

 

* Over 10 years" experience.

* Prompt response.

* OEM & ODM available.

* Support factory inspection.

* Standard qulity control system.

* Different choices of payment and delivery.

* Independant R&D dept, designing dept,to meet your special need.

* Whole set of technical supports and with abroad projects experience.

* We are manufacturer, offer better price better production control.

* Sample order, customized order, bulk order are supported.

* Reliable after-sales service, with one year waranty.

 

Company Information

 

Customers

 

 

Contacts

 

Shenzhen Asenware Test & Control Technology Co.,Ltd.

 

 

 

Words from Julia

Just feel free to contact us now, best service and favorable quotation will be offered to you ! !

 

 

 Fire Alarm Panel   Fire Alarm Panel system   Fire Alarm control Panel  Fire Alarm control system  conventional Fire Alarm Panel   4-32 zone Fire Alarm Panel fire alarm




Send your message to this supplier
* Inquiry Title
* Content
* E-mail
* Security Question

Customer Reviews total 0 items

For product pricing, customiztion, or other inquiries

Contact Supplier

Links