HFC-227 Gas System FM200 gas description
HFC-227 Gas System FM200 gas is an engineered system utilizing a fixed nozzle agent distribution network. The system is designed and installed in accordance with the National Fire Protection Association (NFPA) Standard 2001, "Clean Agent Fire Extinguishing Systems." When properly designed, the FM-200 system will suppress surface burning fire in Class A, B, and C hazards.
The clean agent fire extinguishing system shall perform as outlined in the following sub-sections.
A. Achieve a 6.25% (v/v) extinguishing concentration for Class A (Surface Type Fires) hazards.
B. Achieve a 8.70% (v/v) or greater, as required, extinguishing concentration for Class B (Flammable Liquids) hazards.
C. Achieve a 7.00% (v/v) extinguishing concentration for Class C (Energized Electrical Equipment) hazards.
D. Within 10 seconds, the clean agent fire extinguishing system shall discharge 95% of the required suppression agent mass.
E. The clean agent HFC-227 Gas System FM200 gas fire extinguishing system shall consist of one or more Asenware Fire Systems agent cylinders and related equipment. The cylinders may be either connected to a discharge pipe arrangement separately or connected to a common manifold and discharge pipe arrangement. The agent cylinders shall be filled with FM-200, and super pressurized with dry nitrogen to a working pressure of 360 PSIG at 70°F (24.8 bar gauge at 21°C).
HFC-227 Gas System FM200 gas technical parameters
Tempreture ºC | 0-50 | ||
| 20ºC Storage pressure(Mpa) | 2.5 | 4.2 | 5.6 |
| 20ºCmaximum working pressure (Mpa) | 4.2 | 6.7 | 8 |
| Cylinder (L) | 100 | 70/90/100/120/150/180 | 90 |
| AGENT kg/m3 | ≤1120 | ≤1120 | ≤1080 |
| Nozzal pressure | ≥0.6 | ≥0.7 | ≥0.8 |
| Discharge time | Computer room ≤8 others≤10 | ||
| concentration | 8-10% | ||
HFC-227 Gas System FM200 gas operation

HFC-227 Gas System FM200 gas show


ITEM | ELECTRICAL RATING | COMMENT | |
Mains Supply | 90 to 270VAC, 50Hz/60H(100 Watts maximum) |
| |
Battery Type | Two 12 Volt sealed lead acid in series. | 7Ah maximum | |
R0V Output | Fused at 500mA with electronic fuse | 1.6Amp total load over all circuits | |
Sounder Outputs | 21 to 28V DC Fused at 500mA with electronic fuse |
| |
Fault relay contact rating | 5 to 30 VDC 1A Amp maximum for each | Volt free changeover contact | |
Local fire relay contact rating |
| Volt free changeover contact | |
First stage contact rating |
| Volt free changeover contact | |
Second Stage Contact Rating | 5 to 30 VDC 1A Amp maximum for each | Volt free changeover contact | |
Extract Contact Rating | 5 to 30 VDC 1A Amp maximum for each | Volt free changeover contact | |
No. of detection circuits | Four 21 to 28V DC |
| |
No. of sounder circuits | Thee 21 t0 28V DC | 2 X first stage, 1 X second stage |
FM200 GAS SYSTEM PACKING

Shpping :by sea .
Our services
1.OEM ODM can be provided .
2.Technical support like how to install operate .Any question will be answer within 24 hours .
3.We have prfessional technical team to help customers solve technical problems .
4.Hotel project hospital factory fire alarm system project can be made .
Payment terms :T/T L/C Western union .
Delievry time :usually about 2 to 5 days .Mass product about three weeks .
Warranty :one year
Certificate :CE LPCB ISO9001
Technical support :yes